Ȩ > ǰҰ > SMPS for TV
 
PN120LPS-VF
 
 
 

Application

24 LCD TV & Monitor

Condition

Input Requirements

Voltage

100 to 240Vac rms

Free Input Voltage(with PFC)

Current

5.0Arms

at 90 to 264Vac Input

Frequency

50Hz - 60Hz

 

Efficiency

Minimum 90%

at Maximum load  

DPMS

0.9W Max.

5V/40mA at 230Vac/50Hz

Protection

Over Current Protection

Inrush Current Limiting

Under Voltage Protection

 

 

 

Output Requirements

Voltage

&

Current

+24V/4.0A

+5V/4.5A

+12V/1.0A

+13V/0.5A

+5Vsb/1.0A

4.5Apeak

5.5Apeak

1.2Apeak

0.6Apeak

1.2Apeak

PS_ON

Signal

Logic level low(TTL), Off

< 0.8V while sinking -1.6(0.4V)

Logic level high(TTL), On

Between 2.0V and 5V output

while sourcing -200

Protection

Over Voltage Protection

Short Circuit Protection

Over Current Protection

Apply to +24V,+5V,+12V

Environmental

Requirements

Operating

Storage

-20 to +60

-40 to +80

Temperature

Operating

Storage

10% to 90%

5% to 95%

Humidity (Non-condensing)

Size

185mm(L) * 125mm(W) * 35.8mm(H)

EMI

6dB margin in a functioning unit for FCC and CISPR 22 Compliance with Class B 

Safety

UL, CB Approval

Mechanical Specification